Monitoring of groundwater quality from boreholes around the Yotsugi mill-tailings dam, in the Ningyo-toge Environmental Engineering Center, JNC, have been carried out to estimate extent and quality of contaminated water plume from the mill-tailings pile. In this report, data collected from 1979 to 1998 fiscal year were listed and their spatial and time variation of physicochemical parameters, uranium and radium were also summarized. Additionally, groundwater sampler has been improved and analytical method has been modified. Some results from groundwater quality were; (1)Uranium and radium concentrations were low, although unexpected change was appeared in some borehole. (2)Water table and temperature from boreholes on the left bank of the dam showed drasticaIly change. (3)Etectric conductivity and concentrations of various dissolved ions tend to high from the embankment upward, whereas they tend to low from the embankment downward.