精密抵抗体内の発熱と放熱の研究
カネ子 高橋, 悦郎 山田, 牧夫 佐藤 et al. · Institutional Repositories DataBase (IRDB) · 2009
In this paper, the heat transfer from precision resistance device on transient behavior and steady state temperature field have been studied. The methods using in this investigation are mainly numerical simulation and a little experiment by infrared temperature measurement system. Main results obtained in this study are as follows: (1)The time from switch on to steady state of temperature field is estimated about 20 sec. (2)At the steady state, temperature distributions of Ni foil and near region of it are almost equal value. And out side material around the range stated before are affected on properties and size of out side materials. (3)The attaching of heat pipe or fin decrease the temperature of its neighboring range, however best method for temperature decrease is to increase of heat transfer coefficient of full surface of device.