既存浄水施設の改修による水質改善に関する研究

安弘 和田 · Institutional Repositories DataBase (IRDB) · 2015

Effects of water quality improvement by upgrading existing purification facilities at a Wakayama City Water Supplier were investigated.The results of this study provide a valuable case study for other midscale waterworks departments in Japan.This paper consists of 10 chapters.Chapters 1 and 2 show the outline of Wakayama City Water Utilities.Chapters 3 to 11 show the results of the study in detail.Chapter 3: We evaluated characteristics of water quality data in the Kinokawa River.From 1996 to 2001, total phosphorus (T-P) concentrations increased substantially in the middle part of the river and a large increase was observed when the flow rate was less than 20m 3 /s.Numerical analysis also demonstrated large increases in industrial T -P loads from 1996 to 1999.Chapter 4: In 2000, the Kano Purification Plant introduced facilities for injecting carbon dioxide and slaked lime.As a result, we could detect that calcium carbonate deposits in the water pipes and iron and lead elution in purified water were greatly reduced.In addition, red water decreased significantly and aluminum in the purified water was maintained at low concentrations by injecting carbon dioxide into the raw water.Chapter 5: From 2010 to 2012, the Dejima Purification Plant in Wakayama City introduced a chemical feeding facility of sulfuric acid and sodium hydroxide and a tube settling system.A s a result, the average turbidity of clarified water decreased from 1.0 mg/L to 0.4mg/L, allowing the turbidity of the filtered water to always be maintained below 0.1 mg/L.The pH of purified water satisfied the water quality standard, "Approximately 7.5".Chapter 6: The Dejima Purification Plant introduced a wastewater treatment facility (dehydrator).The facility was rented in order to reduce cost s.A verification test was carried out in 2006.The operation period of the system is 10 years and it ha s been working appropriately.Chapter 7: The Takihata Purification Plant started in August 2003.Trihalomethane concentration in drinking water has been the major issue since the start of the plant.Therefore, some experiments were conducted in order to investigate reducing the trihalomethane concentration by aeration in a distributing reservoir at the plant.The experiment results showed that the trihalomethane concentration decreased exponentially in proportion to the increased amount of aeration.Chapter 8: In 2004, we built a new water examination result database system to use the water examination data effectively.In this system, the computers used with the water quality instruments, the office computers, and a hard drive were networked together using the internet.General-purpose spreadsheet software was used for the system.Chapter 9: It is necessary to control the concentration of chloric acid in tap water.However , it is difficult to do so because the concentration of chloric acid in sodium hypochlorite gradually increases when it is stored, and measuring the concentration of chloric acid using ion chromatography is time consuming.In order to solve this problem, a new reliable and simple method for accessing the concentration of chloric acid in the tap water without using ion chromatography was developed in 2008.Chapter 10: In this paper, it was discussed that the Wakayama City Waterworks Bureau's existing purification facilities were updated using the most cost-effective methods available, without the need to renew them on a large scale.As a result, appropriate water quality was able to be maintained even when the quality of the raw water deteriorated or when drinking water quality standards were raised.These results are useful as a feasible model case for small and medium-sized entities. 既存浄水施設の改修による水質改善に関する研究

Cited by 0 works. doi:10.19002/sk0076 Open-access PDF

Authors