光学式モーションキャプチャシステムと加速度センサおよびジャイロセンサを用いたウェアラブル端末型モーションキャプチャシステムによる動作解析比較(原著)
雅博 安保, 智之 鈴木, 寿都 河治 et al. · Institutional Repositories DataBase (IRDB) · 2018
平成 30 年 8 月 31 日)To inform the mechanism how to improve the abilities of patients, outcomes of rehabilitation should be evaluated.When rehabilitation outcome are quantifi ed or visualized, they greatly contribute to rehabilitation treatments.In the present study, we compared, via acceleration and gyro sensors, the Vicon optical motion capture system and the Moff-Soku wearable device -based motion capture system.Each physical motion was simultaneously recorded with each motion capture system.Because the Vicon motion analysis system is now the most accurate, we examined its correlation with the Moff-Soku systems.Variables of upper limb motion, such as the shoulderʼs range of motion, were measured in 8 volunteer subjects.We found that, the average difference of each range of motion between the systems was 2.65 to 5.62 degrees.We believe that errors of Moff-Soku systems can be reduced if its bands are attached at more appropriate positions, or if trunk rotation more restricted.The Moff-Soku wearable device-based motion capture system is less expensive, easily used, and can be applied to various motion analysis environments.This system deserves widespread acceptance for quantifying or visualizing outcoms of rehabilitation.
Cited by 0 works. Open-access PDF