Метод гнучкого визначення міжповірочних інтервалів засобів вимірювальної техніки
Yevhen Ryzhov, Lev N. Sakovich, С. М. Семеха et al. · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2026
Based on an analysis of the existing system for calibrating measuring instruments (MI), a transition to a flexible approach to determining calibration intervals (CI) is proposed instead of the existing one, where CI value is constant throughout the entire period of MI operation. This allows for an increase in the metrological reliability (MR) of measuring instruments and the accuracy of determining the technical condition (TC) during the maintenance and repair of radio-electronic equipment (REE) of weapons and military equipment. The article proposes, based on the use of modern information technologies with the application of computers by metrological authorities, to individually and scientifically justify the assignment of CI to specific models of MI depending on their operating conditions, intended use, requirements for reliability or accuracy of measurements of REE parameters, and the capabilities of metrological bodies to restore the values of MR or the accuracy MI during their verification. Functional dependencies of the quality indicators of measuring instrument verification on controlled variables have been obtained. It has been shown that the greatest influence on the length of CI is exerted by the technological capabilities and qualifications of the specialists of the metrological body performing the verification of MI. The structure of the method implementation is presented and the algorithm for its practical application in modern conditions is formalized. Examples of use are given, which confirm the possibility of preserving the necessary values of MR and the accuracy of parameter measurements throughout the entire period of operation of MI, which is the effect of using the method. The scientific novelty of the proposed method lies in taking into account the operating conditions (value φ) and restoring the MH of specific MI samples (values α and β) in metrological bodies during their verification, which is absent in domestic and foreign scientific publications. The effect when using the method is achieved by a flexible approach to justifying the value of CI depending on the controlled variables τi (φ, α, β). This does not significantly increase the number of verifications of measuring instruments (n) over the entire period of their intended use, but ensures the requirements for determining TC of REE with the necessary reliability. The results obtained should be used in existing metrological bodies that perform calibration of measuring instruments.
Cited by 0 works.