К вопросу автоматизации рудничного подъема с асинхронным приводом при скипах с донной разгрузкой

Ф. Н. Шклярский · Journal of Mining Institute · 1954

Lift automation at skips with bottom unloading in the period of deceleration can be realized by application of dynamic braking mode of asynchronous lifting motor. In Fig. 1 the calculated diagram of velocity during the deceleration period t₃ is shown by the dotted line λr. During the unloading period t₄', a constant velocity v₃ (line ρϕ) is assumed, which drops to zero during the period t₄ along the line ϕф. According to the force diagram of the induction machine shown in Fig. 2, the acceleration of the hoisting motor during the start-up period occurs along the broken line BCDEFGHIKLT, varying about the given (design) force value F₁ as about the average value between the extreme limits F₁' and F₁". At the end of the start-up period, there is a full stroke period during which the driving force follows all changes in the static force. Assuming a statically unbalanced lifting system, let the static force, and hence the driving force developed by a motor operating on the natural characteristic R₂, vary from the value of F's₂ at the beginning of the full stroke period (point N') to the value of F"s₂ at the end of this period (point N). At the end of the full stroke period, there comes a deceleration period t₃, during which a braking mode is assumed, which is implemented in the form of dynamic braking. An asynchronous machine from the motor mode on characteristic R₂ at speed vₙ is switched to dynamic mode by switching the stator from alternating current to direct current.

Cited by 0 works.

Authors