CFD解析を用いた気泡分離除去装置の性能評価
清子 坂間, 遼 高見澤, Yutaka Tanaka et al. · Institutional Repositories DataBase (IRDB)
Air bubbles in working fluids greatly influence the performance of hydraulic systems.The bubble in working hydraulic fluids may cause major problems because of bulk modulus change, cavitation and aeration inception, degradation of lubrication, noise generation, oil temperature rise, and deterioration of oil quality.An active "bubble eliminator" that uses swirl flow to remove air bubbles can be used to mitigate these problems.The purpose of this paper is to evaluate an adequate computational model and mesh with CFD analysis according to the numerical simulation of the bubble eliminator.It has been numerically verified that the performance of the bubble removal for the bubble eliminator depends on particle sizes of bubbles by Euler multiphase model.It is also confirmed that the numerical results have good agreement with experimental results.
Cited by 0 works. doi:10.15002/00022808 Open-access PDF