台風シミュレーションを用いた免震ダンパーの累積損傷評価

聖生 馬橋, Sei Mabashi, 大樹 佐藤 et al. · Institutional Repositories DataBase (IRDB)

From the experience of numerous earthquake disasters, the interest in isolation structure is rising.Recently, seismic isolation structures have been actively adopted in high-rise buildings as the isolation technology improves.However, when adopting the seismic isolation structure in a high-rise building, its usefulness is questioned against wind loads having properties different from those of earthquakes, and one of the issues is to evaluate fatigue damage degree of the seismic isolation damper.In this study, we analyze the wind response using wind external force created based on the typhoon simulation and show the adequate wind direction and the validity of the equivalent duration in the 10 minute evaluation shown in the current wind resistance design guidelines.

Cited by 0 works. Open-access PDF