精密分析用ガス透過システムの設計とガス透過/フローインジェクション法によるアンモニア態窒素の吸光光度定量

慶郎 樋口, 亜希子 井上, 知則 坪井 et al. · Institutional Repositories DataBase (IRDB) · 1999

A new on-line gas-permeation system was developed to enhance the efficiency and stability of gas permeation for a long time, and was applied to the determination of ammonium ion in river-water samples by the flow- injection method. The proposed gas-permeation system consists of a newly designed gas-permeation unit, a sample injection valve, a reaction coil and two six-way rotary valves in a constant-temperature oven. The gas- permeation unit was assembled using an inner micro porous polytetrafluoroethylene (PTFE) membrane tubing and an outer glass tube, which could be easily connected with one another using connectors with ferrules and o-rings. A sample solution was injected into a carrier containing 0.02 M sodium hydroxide, in which ammonium ion was converted to gaseous ammonia. The gaseous ammonia generated in the carrier passed through the micro porous PTFE membrane, was absorbed in a reagent solution and changed the pH of the reagent solution, which resulted in a color change to cresol red. The absorbance change of cresol red at 550 nm was measured using a visible detector with a flow cell (8μl, 10mm path). After the measurement, two six-way rotary valves were switched over from the flowing state to the drain state of the gas-permeation unit, and the residual solutions in the gas-permeation unit were removed and the PTFE membrane tubing was dried. By keeping the temperature of the oven at 40℃, the sensitivity and the reproducibility for the determination of ammonium ion was improved. Furthermore, the efficiency of gas permeation through the inner tubing could be kept high and constant for a long period without any procedure for reactivating the porous PTFE membrane tubing. Calibration graphs for ammonium ion were liner over ranges of 0 to 10 ppm and 0 to 1.0 ppm of N-NH(4)(+), and the sampling rate was 30 samples per hour. The detection limit for N-NH(4)(+) was about 0.01 ppm when the effective length of the membrane tubing was 5 cm. By using the proposed FIA system, ammonium ion in river-water samples was determined. The analytical results obtained by the proposed method showed a good correlation with those obtained using the indophenol derivatization/FIA method. The relative standard deviations of ten injections were 0.51% and 0.83% with concentrations of 2.73 ppm and 4.11 ppm, respectively. The recoveries of ammonium ion were found to be 97~98%.

Cited by 0 works. Open-access PDF

Authors