傾斜型熱線流速計による軸流圧縮機内部の3次元計測

隆王 熊谷, 英穂 田中, 秀雄 丸田 et al. · Institutional Repositories DataBase (IRDB) · 1980

To measure three-dimensional air flow in the axial flow compressors, several kinds of slanted hot-wire anemometery techniques have been developed in recent years. Quick response and less disturbance to the flow are the typical advantages of this method of measurement. In our experiment, the measuring system consists of a hot-wire anemometer with a single slanted wire probe and a data processing system. Exit flow of the axial flow compressor with 15 rotor blades is measured by the system. The anemometer output signals, obtained by locating a probe at three positions in each 120deg orientations, are sampled, averaged and calculated using the directional consines techinque. The resulting processing data show the values for three-dimensional components of mean velocity, swirl angle and pitch angle. The decay and the diffusion of the rotor wakes are also presented.