滋賀医科大学歯科口腔外科学講座における骨銀行の現状 : 無菌脱灰活性骨を用いた顎骨再建の臨床成績

Gaku YAMAMOTO, Kozo Sakamoto, 一寿 北中 et al. · Institutional Repositories DataBase (IRDB) · 2001

Our department established a bone bank using autolyzed, antigen extracted, allogeneic bone (AAA bone) in which the immunogenicity is markedly reduced by chemical treatment, and has started its clinical application to reconstruction of bone defects. An outline of the bone bank and the clinical results are reported. The graft used AAA bone prepared by chemically treating (e.g. decalcification using hydrochloric acid) cortical bone of human long tubular bones of the upper and lower limbs. In 1994, we first decided to transport AAA bone from the Federal Republic Germany to Japan for clinical application. We also recruited domestic donors by asking neighboring hospitals to provide excess bone fragments resected in plastic surgery of the jaw and lower limbs amputated from severely diabetic patients due to peripheral necrosis. These procedures were carried out with the approval by the Safety Measures Division, Drug Safety Bureau, Ministry of Health and Welfare and the Ethical Committee of our University. The donors were selected according to the donor qualification criteria of the Japan Orthopedic Society and with sufficient precaution against infection of Creutzfeldt-Jakob disease. Four limbs (of 4 patients) have been provided to date, prepared into AAA bone by chemical treatments at our department, and used clinically. AAA bone implantation has been made in 16 patients to date. They were 12 males and 4 females aged 15 to 65 years. Their diseases were mandibular cysts in 13, odontoma in 1, fracture of the mandible in 1, and malignant tumor of the mandible in 1. Postoperative panoramic radiograms were obtained in 6 patients with mandibular cysts 2 years or longer after surgery, and the state of bone formation at the implantation site was observed. The oral cavity was also examined for abnormalities, and the percent efficacy was calculated from the results of both examinations. The usefulness rating was very useful in 4 and useful in 3, with a percent efficacy of 100%. The results were satisfactory also in patients followed up for a shorter period after surgery. AAA bone was removed due to infection in only 1 patient, but none of the recipients developed a serious complication. The maximum followed-up period to date is 4 years and 7 months. The postoperative course has been uneventful in all patients, with none showing abnormalities. From these results, AAA bone is considered to have the following merits: (1) By sterilization with EO gas and vacuum packing after preparation, AAA bone can be preserved at room temperature, be used at any time, and is easy to handle. (2) It is highly plastic and can be readily adjusted to various forms during surgery. (3) Implanted AAA bone is completely replaced by the recipient bone. (4) The degree of bone formation at the implantation site can be easily evaluated by radiography.

Cited by 0 works. Open-access PDF

Authors