長尺ナトリウム液位計ナトリウム中試験
久門 靖尚, 等 荒木, 中本 香一郎 et al. · Institutional Repositories DataBase (IRDB) · 1984
It is planed that induction type level-meter of effective measurement length about 5m is installed for monitoring of sodium level in reactor vessel of "MONJU" Plant. Length of level-meters made so far were less than 2m. So long length level-meter which had same length for real plant was fabricated, and in-sodium tests for confirmation of performance as "MONJU" plant instrument were conducted. From these tests, it was found that "MONJU" plant require ment on measurement accuracy (4\%) was satisfied, and prospect of design and fabrication for real plant was obtained. And some propositions were given which were about improvement design of the level-meter property and caution at the installation into the reactor vessel.
Cited by 0 works. Open-access PDF