「常陽」異常反応度監視システムの検証試験; 「常陽」データ処理装置の機能試験
誠 妹尾, Seiji Tamura, 坂口 俊英 et al. · Institutional Repositories DataBase (IRDB) · 1980
Anomaly reactivity monitoring program which is one of functions of Joyo data reduction system was tested under various plant conditions during power ascension testing period. The program is based on a reactivity balance of measured reactivity and known reactivity, and is to detect unknown (or anomaly) reactivity. As consequences of the testings, following results were obtained. For each change of power level and coolant temperature, reactivity change of more than 10cent was induced, the program, however, indicated no trace of any anomaly reactivity. While for change of coolant flowrate of 20\%, approximatly 3cent error reactivity was detected due to, probably, mismatch of thermal constants in the program. Through these testings, it was cleared that the modeling of the program is well simulating the reactor kinetics within 2cent of error except for the change of flowrate. In normal operation, since flowrate is held constant, the error due to flowrate is insignificant.
Cited by 0 works. Open-access PDF