Dose equivalent rate around the fuel handling machine, the control rod handling machine, stand pipe compartment, maintenance pit were measured during gamma ray measurements from HTTR fuel, which was called as “power distribution measurements". The power distribution measurement was the first time to handle the fuel blocks irradiated in the core. Dose equivalent rate measurement aiming the check of shielding performance of components, the check of unexpected streaming path. The radiation monitoring during operation was carried out. As the results, there was no problem on shielding. The measured data at operation condition were also obtained. The data will be useful to expect operation circumstance in the future.