多孔質ハイドロキシアパタイト溶射インプラント体界面の組織学的観察

晴彦 磯部 · Institutional Repositories DataBase (IRDB) · 1996

Implantation of the hydroxyapatite-coated implant into the jaw has been available for some time. However, the success rate of this implant does not seem to be high in comparison with other osseointegrated type implants. So attention was paid to the characteristic biocompatibility of the porous HA coated implant. Therefore, the purpose of this investigation was to observe the histological study of interface of porous HA coated implant under the light microscope and the scanning electron microscope during and experiment with Japanese monkeys. In the histological findings 3 months after implantation, newly formed bone tissue was observed surrounding the implant at the light microscope level. The porous HA coated implants were encapsulated with the newly formed bones. On the other hand, the implant was surrounded with newly formed bone tissue, but the surface of newly bone was adjacent to the macrophage-Iike giant cell without an inflammatory reaction at some patrs. At 6 months after implantation, a large amount of newly formed trabecular bone was seen on the surface of HA coated layer of implant. Immature osteoid tissue was found in the interstice of the HA coated layer at 6 months after implantation. However, it seemed that interstiate collagenous tissue at 12 months after implantation. Those results suggest that the porous HA coated implant must be stabilized to external forces.