新潟市に建設された住宅における室内温熱環境とエネルギー消費量に関する実測調査 : 全電化・高気密・高断熱住宅を対象として
淳 坂口, 伸一 赤林, 山口, 一 · Institutional Repositories DataBase (IRDB) · 2001
The investigation for indoor thermal environment and energy consumption in air-tight house was carried out. The results are as follows, (1) The thermal environment in summer and winter season, the temperature of the living room is varied from 20℃ to 28℃. (2) In summer, electric energy consumption of the air conditioner and the hot water is about 30% respectively, the refrigerator is about 11%, lighting is about 3%, the mechanical ventilation is about 7% and the electromagnetic cooking heater is about 4%. (3) In winter, electric energy consumption of the floor heating is about 44%, the hot water is about 23%, the lighting and the electromagnetic cooking heater is 1% respectively, the refrigerator is about 3% and the mechanical ventilation is 2%.