履歴ダンパーを設置した超高層建物の最適ダンパー量時の実効変形比
Yuya Sawa, Yuya Sawa, 大樹 佐藤 et al. · Institutional Repositories DataBase (IRDB) · 2021
The placement and number of passive dampers employed in building greatly affect the response reduction, thus, must be considered in designing. In the previous study considering only one damper layout plan and constant damper ductility demand, the effective damper deformation ratio of optimal shear coefficient to be the median value was confirmed. In this paper, several damper layout plans and different damper ductility are considered, and the effective damper deformation ratio of optimal shear coefficient and of maximum equivalent damping ratio in order to clarify the relationship between the effective damper deformation ratio and damper ductility demand are compared.
Cited by 0 works. Open-access PDF