小リークナトリウム水反応試験研究 第4報; 蒸気ウエステージと検出計の応答

根井 弘道, 氏原 幸三朗, 大内 義弘 et al. · Institutional Repositories DataBase (IRDB) · 1974

This report describes the results of the thirty five test runs conducted by the small-leak sodium-water reaction testloop (SWAT-2) in the period of August 1976 throngh May 1974. The ohjectives of the work is to determine the effects of various parameters on material wastage during small leak of super heated steam into sodium and to examine characteristics of the responses of various leak detectors after the steam injections into sodium. The following tests were made in the period described above. (1)Full penetration of a target tube by wastage. (2)Measurement of temperature on a target tube surface during sodium-water reactions (3)Wastage rate of a target tube with use of a nozzle with 0.2mm diameter (4)Responses of detectors of hydrogen in sodium or argon gas after super-small leaks of steam into sodium by usiug capsule Material wastage tests with steam injections into sodium have been performed. The test conditions of sodium velocity past target of spacing between nozzle and target, and of sodium and steam temperature were same as ones described in previous report. The nozzle diameter was 0.2$\sim$1.0mm. A target material was a 2.25Cr-1Mo steel and stainless steel. Inspection of the contour map and sectional view of wastage area showed that the depth distribution was expressed by a normal curve of error for most ranges of leak rate tested. Tube penetration tests were conducted to evaluate the size of penetration hole on the target tube, and time which is from starting of steam leaks to tube failure. A process of the propagation of tube failure was discussed assuming the depth distribution of wastage area to be a normal curve of error. An experimental equation was presented to predict the wastage rate as a function of the leak rate and the sodium temperature for 2.25Cr-1Mo steel and stainless steel respectively. Temperature distributions on the target tube were very similar to the wastage patterns. Maximum temperature measured on the target tube ...

Cited by 0 works.

Authors