Background. Steady-state thermal resistance does not provide a complete characterization of multilayer building envelopes under time-varying thermal conditions because it does not account for the spatial distribution of thermal inertia or the excitation regime. Subject of the study: the dynamic thermal response of a stationarily equivalent three-layer wall assembly under periodic and finite-pulse thermal loading. Objective: to assess the effects of layer order, temperaturedependent thermophysical properties, and compensated interfacial thermal resistance at unchanged total steady-state thermal resistance. Research tasks. To define the B, O, N, C5, and C10 scenarios; determine regime-appropriate response metrics; and assess the numerical robustness and resolvability of the resulting effects. Methods. A one-dimensional transient heatconduction model with Robin boundary conditions, finite-volume discretization, implicit Backward Euler time integration, Picard iteration, energy and interface diagnostics, and grid/time refinement was used. Results. All configurations were constrained to Rtot = 3.65315 m²K/W. The combined grid/time numerical uncertainty was 0.325166% against the adopted 0.5% threshold. For the investigated B/O pair, the relative effect changed sign from −0.905363% under periodic loading to +0.56625% under finite-pulse loading, with effect-to-uncertainty ratios of 79.2365 and 88.85, respectively. For N, the periodic effect of −2.00484% was numerically resolved, whereas the finite-pulse effect of −0.282142% remained unresolved. The C5/C10 effects were also numerically unresolved. Conclusions. Controlled stationary equivalence combined with numerical-uncertainty assessment enables regime-dependent effects to be separated; the observed sign reversal is restricted to the investigated B/O pair and the adopted regime-specific metrics.
Cited by 0 works. doi:10.26906/sunz.2026.3.047 Open-access PDF
Authors
References
- Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass
- Effect of Insulation Location on Initial Transient Thermal Response of Building Walls
- Configuring wall layers for improved insulation performance
- Design criteria for improving insulation effectiveness of multilayer walls
- Experimental determination of time lag and decrement factor
- Determination and verification of thermal response factors for thermal conduction applications
- Estimation of thermal impulse response of a multi-layer building wall through in-situ experimental measurements in a dynamic regime with applications
- Impact of Insulation Type and Thickness on the Dynamic Thermal Characteristics of an External Wall Structure
- In-situ rapid determination of walls’ thermal conductivity, volumetric heat capacity, and thermal resistance, using response factors
- An Analytical Solution for Transient Heat Conduction in a Composite Slab with Time-Dependent Heat Transfer Coefficient