Дослідження невізуального впливу світлодіодного світильника
Olena Didenko, Л. Назаренко, Olena Liashenko et al. · Scientific periodicals of Ukraine · 2026
The aim of the work is to study the non-visual impact of an LED luminaire with a correlated color temperature of 6500 K using available tools (electronic spreadsheets) and methods for determining the circadian stimulus. The spectral power distribution of the luminaire and electronic spreadsheets in the WELL Building Standard has helped to determine the melanopic ratio (in other sources – the melanopic/photopic ratio), which is the ratio of melanopic illuminance to photopic illuminance for a given light source. The CIE S026 Toolbox has allowed to evaluate an α-opic action for S-cones, M-cones, L-cones, rhodopic and melanopic sensitivity, illuminance, irradiance, luminous efficacy, daylight equivalent (D65), efficacy of luminous radiation (ELR) for daylight (D65). Experimentally, the horizontal illuminance on the desktop and the vertical illuminance at the level of pupil of the eye were determined under conditions when the employee looks forward (at the monitor) and when looking at the desktop (head tilted). Using CS Calculator (2.0), the circadian stimulus and melanopic equivalent daylight illuminance (M-EDI) were determined and the results of calculation were compared with values in CIE S026 Toolbox. Recommendations are proposed for using such a luminaire to create comfortable condition with sufficient non-visual impact to maintain human health in the workplace according to current standards.
Cited by 0 works.