ВИМІРЮВАЛЬНИЙ СТЕНД ДЛЯ ДОСЛІДЖЕННЯ ПЕРЕХІДНИХ ПРОЦЕСІВ В ПЛІВКАХ ТЕЛУРИДУ КАДМІЮ

Ксенія Олександрівна Мінакова, Антон Миколайович Дроздов, Андрій Ігорович Доброжан et al. · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2026

Considered is the problem of reliable protection of modern electronic equipment against the destructive impact of powerful microwave and subnanosecond electromagnetic pulses. Attention is focused on the fact that traditional protection elements are unable to function effectively in the subnanosecond time range due to significant response delay time or high intrinsic capacitance. The prospects of using thin-film semiconductor structures based on cadmium telluride for the creation of high-speed protective devices due to their ability to threshold switching into a highly conductive state are analyzed. The circuit implementation of an experimental measuring test bench for generating high-voltage nanosecond pulses and precision recording of transient processes is described. The technique of manufacturing experimental samples by thermovacuum deposition of cadmium telluride films on molybdenum foil is shown. The design features of the strip-type mounting equipment, which ensures reliable fixation and the possibility of statistical express measurements without dismantling, are considered. The voltage-time dependencies obtained during the impact of load pulses are analyzed. The presence of rapid switching processes of the material between states with low and high conductivity is confirmed, and the critical threshold voltage corresponding to electrical breakdown is determined. The dynamics of electrical signal changes after the end of the exciting pulse using an integrated bias circuit is considered. It is shown that instead of the expected monotonic voltage drop, pronounced high-frequency oscillations with a change in polarity occur. It is confirmed that as a result of the interaction between the capacitance of the open structure and the inductance of the lines, the measuring system enters the oscillatory circuit mode. Attention is focused on the fact that the amplitude of these oscillations makes direct observation of the charge state relaxation processes of the material impossible. It is concluded that the proposed circuit solutions are suitable for studying the damping of oscillations, but require optimization for an accurate analysis of the charge carrier lifetime.

Cited by 0 works. Open-access PDF

Authors