Перетворення еквівалентних теплових схем електричних машин.
Г. И. Шевчук, С. С. Нестеренко, С. Н. Поизд · ELECTRICAL AND COMPUTER SYSTEMS · 2019
The general rules are given according to which the thermal circuits are transformed by excluding structural elements and flow elements of the cooling medium from ETS in order to reduce the order of the control system. For the first time, the method of excluding elements of the flow of the cooling medium is presented. Il 1. Bibliogr .: 2 titles.