Розрахунок зовнішнього магнітного поля фазних обмоток електричних машин змінного струму в відсутності феромагнітних сердечників.

В. А. Яковенко, В. Г. Соловьев, В. В. Сотников · ELECTRICAL AND COMPUTER SYSTEMS · 2019

The expressions for calculating the external magnetic field (VMP) of the phase windings of AC electric machines in a spherical coordinate system are derived. It is shown that the high-frequency magnetic field of a 2p-pole m-phase winding is mainly determined by a magnetic multipole, which varies with distance in proportion to 1 / R0 ^ (p + 1), and near the winding - by a multipole, which changes according to the law 1 / R0 ^ (p + 3). The maximum value of the VMP reaches in a plane passing through the center of the winding; along the longitudinal axis of the winding, the field value is zero. Bibliography: 3 titles.

Cited by 0 works.

Authors