Коефіцієнт використання двигуна в електроприводах з тиристорними перетворювачами
Л. М. Поляков, П. Э. Херунцев, Б. И. Шкловский · ELECTRICAL AND COMPUTER SYSTEMS · 2019
The results of an analytical calculation of motor utilization factor values in thyristor DC drives without a shunt diode are presented. A formula is proposed for determining the required load parameters to ensure a given Ri. A comparison is made of utilization factors in shunt diode circuits and without a shunt diode with separate and consistent control.