Индукционно-термическое вакуумное нанесение ниобий-содержащих покрытий на титан
Marina Alekseevna Fomina, Vladimir Aleksandrovich Koshuro, Aleksey V. Voyko et al. · Vestnik MEI · 2026
It has been determined that, as a result of induction thermal vacuum sputtering, a niobium target is sputtered at an operating current of 500…700 A, a current frequency of 44 kHz, and a chamber pressure from 1.0…1.1 to 1.5…1.6 mm Hg. Regularities in the changes in the niobium and oxygen content on the coating surface of titanium disk samples obtained by induction thermal vacuum sputtering (ITVS) have been revealed. Experimental studies have shown that an increase in the exposure time during ITVS of niobium has an effect on the modified layer thickness and on the microhardness of niobium-containing coatings. The maximum microhardness of the coatings equal to around 16…21 GPa corresponds to an operating current of 500…600 A with a high-temperature exposure of 300…600 s.
Cited by 0 works.