Современные подходы к хирургическому лечению пороков трикуспидального клапана

Назим Низамович Шихвердиев, Г. Г. Хубулава, С. П. Марченко et al. · Medical Almanac · 2013

There was analyzed the experience of the surgical treatment of 228 patients with tricuspid valve (TV) failures. 122 patients underwent isolated prosthesis or plastic surgery of TV. For 124 patients the interventions on TV were associated during surgical treatment of other valves failures. In case of isolated TV prosthesis the lethality rate was 8,1% (the lethality rate for this group by Euroscore is 16,1%), and in case of TV plastic surgery – 2,1% (predictable lethality – 5,3%). Reconstructive interventions on TV provided high percentage of survivability and almost full absence of specific complications at the distant dates. The use of mechanic prostheses in tricuspid position was followed by high frequency (8,9 %) of their thrombosis and thrombendocarditis, this demanded the repeated intervention. The average period before reprosthesis was 2,7 years, which makes even the young people to undergo the TV bioprosthesis. The authors recommend to perform TV operations on the working heart in the conditions of parallel AC without aortic compression.

Cited by 0 works.