Использование толерантного внутриглазного давления в практической офтальмологии
Мачехин Владимир Александрович · Tambov University Reports Series Natural and Technical Sciences · 2015
Purpose. To compare the values of tolerant and real intraocular pressure in patients with different stages of glaucoma, as well as in glaucoma suspects and patients with healthy eyes. Material and methods. 53 patients (97 eyes) aged 52-85 (range, 68.7 ± 8.4) years old were examined. 20 patients were men, 33 were women. Tolerant intraocular pressure was measured according to the table and formula offered by S.V. Balalin. Besides, the routine ophthalmological examination, standard automated perimetry, HRT, biometry, pachymetry, the measurement of blood pressure and mean value of true IOP according to 5-10 measurements during a long follow-up were performed to all patients. Results. It was noted that in 81 % of cases the difference between the calculation results of tolerant pressure according to the table and formula did not exceed 1.0-1.5 mm Hg and there was observed the appropriate increase in the number of eyes with marked exceeding of the mean P 0 in comparison with tolerant IOP as far as glaucoma progressed. Conclusion. The individual tolerant pressure calculation according to the formula is more accurate but in outpatient service It is possible to use a tabular version.