二尖瓣(机械瓣)置换病人抗凝期间栓塞相关并发症的原因分析
张国报, 乔刚, 程兆云 et al. · 2009
Objective: To evaluate the causes and control strategies of thrombosis in mitral valve (mechanical valve) replacement patients. Methods: 109 cases of valve replacement patients were retrospectively analyzed. Results: All the 9 cases of thrombosis-related events were mitral valve replacement patients, one case of acute valve thrombosis, 6 cases of TIA, 2 cases of cerebral embolism. The plasma fibrinogen content in TIA patients was higher than that in non-TIA patients. Conclusion: The start time and optimal level of anticoagulation should be individualized. The Plasma fibrinogen content increasing can lead to TIA. High risk patients Should be monitored strictly, especially during reducing dose process of warfarin adjustment.