Исследование способа компенсации анормальных гармоник двухмостового преобразователя с параметрической несимметрией

Тараканов Вячеслав Павлович, Вахнина Вера Васильевна, Кувшинов Алексей Алексеевич · Vektor nauki Tol yattinskogo gosudarstvennogo universiteta Seriya Ekonomika i upravlenie · 2015

The article covers the issue of equalizing of abnormal current and voltage harmonics caused by parametric asymmetry of commutation circuits of multi-bridge converter. The difference of commutation circuit interphase inductance and inductance between individual valve bridges of multi-bridge converter (for example, when using transformers with a star, delta, zigzag or extended-sided delta valveside winding connection) is represented by a really distinct asymmetry, leading to the production of the input current and output voltage abnormal harmonics unusual for the idealized mode. The authors studied the conditions for minimization of the rectified voltage harmonics caused by inequality of commutation circuits inductance of two series-connected valve bridges of twelve-pulse converter by the asymmetry artificially introduced into control angles, and evaluated the effectiveness of technical implementation. We obtained the dependencies that determine the condition for minimization of abnormal harmonics of the output voltage and input current of twelve-pulse converter caused by inequality of valve bridge commutation circuits. The authors obtained a relationship which makes it possible to control a multi-bridge converter by introduction of correction into control angles of valve bridge allowing to reduce the level of abnormal harmonics in the output voltage and input current of a twelve-pulse converter caused by the parametric asymmetry of commutation circuits of certain valve bridges. The equalizing of abnormal harmonics caused by the parametric asymmetry can be carried out by the introduction of an additional channel into converter control system; this channel corrects the valve bridge control angles and implements the minimization condition. The simplicity and efficiency of the equalizing method based on the forming of a correction signal of valve bridges control angles through the use of the most accessible for technical implementation parameters as the feedback signals determine the appropriateness of its use in converter equivalent circuits for different purposes and allow to improve their electromagnetic compatibility with a supply system.

Cited by 0 works.

Authors