Скрининговая диагностика проминирующих образований глазного яблока

Aniya F. Gabdrakhmanova, А. А. Александров, Г. Р. Галлямова · Медицинский вестник Башкортостана · 2013

The study involved 23 patients with inside protruding formations of the eyeball. A comprehensive study on the portable device My Sono U5 has allowed to detail location, protrudsion, the width of the base of pathologic formation, the presence of vascularization and to define blood flow dopplerographic parameters. The mostly often observed localization of protrude was postequatorial one 13 cases (56.6%), predominantly we observed juxtapapillaire location of protrude formation (in 12 cases). In the Doppler mode with the use power and / or Doppler we have revealed pathological vascularization as color locus (CL) in protruding tissues in 14 cases (61%), which is generally typical for choroidal melanomas. Most often neogenic vessel that feed the pathological formation was found at base of the protrude formation in 10 cases (71%). Parameters of blood flow velocity in ophthalmic artery on the side of pathological formation were reduced twice in comparison with the data of a healthy eye (p ≤ 0.01). The method of portable ultrasound examination can provide a necessary and sufficient information for the primary diagnosis of intraocular melanoma and can afford to narrow differential diagnoses for diseases of posterior segment of the eye.

Cited by 0 works.

Authors