羟基磷灰石/聚乳酸-三亚甲基碳酸酯软腭植入材料的生物相容性与安全性

汪建, 付晓燕, 熊敏 et al. · 2008

BACKGROUND: Currently commonly used palatal implant material is polyethylene terephthalate (PET), but its clinical application is restricted due to its high price, mild rejection reaction and uncertain long-term biological effect. OBJECTIVE: To evaluate the biocompatibility and safety of hydroxyapatite and poly (d, l-lactide-co-trimethylene carbonate)complex (HA-P) palatal implant material versus PET. DESIGN, TIME AND SETTING: The randomized controlled animal experiment was performed between October 2006 and May 2007 at Biological and Artificial Bone Laboratory, Department of Medical Experiment, General Hospital of Guangzhou Military Area Command of Chinese PLA and Experimental Animal Center of Guangzhou Medical University, Guangzhou, Guangdong Province, China. MATERIALS: Hydroxyapatite (HA) was obtained from Biological and Artificial Bone Laboratory, Department of Medical Experiment, General Hospital of Guangzhou Military Area Command of Chinese PLA (China), Poly (d, l-lactide-co-trimethylene carbonate) (DL-TMC)was produced by Jinan Daigang Biotechnology Co, Ltd. (China). PET, 1 cm in length and 2 mm in diameter, was provided by Department of Otolaryngology, General Hospital of Guangzhou Military Area Command of Chinese PLA (China). HA-P was made using organic solvent injection mould. METHODS: Sixty Sprague-Dawley rats were selected for the experiment. Twenty rats were implanted PET and HA-P into left and right back muscles, respectively, Twenty rats were implanted HA and DL-TMC into left and right back muscles, respectively. Another twenty rats left were performed the same operation but implanted nothing as control. MAIN OUTCOME MEASURES: At 14, 30, 60, 90 days postoperation, implanted materials, surrounding tissues, rat heart, liver and kidney specimens were observed through gross specimen observation and histological examination. RESULTS: All 60 rats were involved in result analysis. Inflammatory reactions of HA and DL-TMC were relatively severe and DL-TMC could degrade in vivo slowly. There was no significant inflammatory reaction of PET and HA-P, They combined closely with surrounding tissue and tissue could grow into moicropores of material, PET and HA-P had no significant degradation during observation period, HA, PET, HA-P and DL-TMC were not harmful to local tissue and systemic organs. CONCLUSION: The biocompatibility and safety of HA-P was similar to PET, but better than HA and DL-TMC.

Cited by 0 works.

Authors