Результаты имплантации полимерного микрошунта под контролем контактной оптической когерентной томографии: пилотные исследования
Ю. А. Масленникова, Сметанкин Игорь Глебович · Medical Almanac · 2015
The aim of the study was to evaluate efficacy of a polymeric microshunt implantation under contact optical coherent tomograrhy (OCT) control in open-angle glaucoma surgical treatment. Under a supervision there were 30 patients (30 eyes) with open-angle glaucoma with high level of intraocular pressure (IOP). Incomplete deep sclerectomy with implantation of a polymeric microshunt of original construction was performed in all patients. A complete ophthalmologie inspection including contact optical coherent tomograrhy of anterior chamber structers as intraoperative and in postoperative period is conducted before and after the operation. It is shown that antiglaucomatous operations with the use of a microshunt carried out under the OCT-control provide a good hypotensive effect for all period of supervision, stabilize visual functions, that allows to regard this method as a perspective in open-angle glaucoma surgical treatment.
Cited by 0 works.